jueves, 25 de abril de 2013

Tapping Machine RE24.C. Programming the driver. Deleting or Restoring Parameter Default

Tapping Machine RE24.C. Programming the driver. Deleting or Restoring Parameter Default.

Video Restoring Parameter defaults.



According to Manual Digitax ST User Guide Control Techniques:



5.6.6 Restoring parameter defaults


Restoring parameter defaults by this method saves the default values in the drive’s memory. (Pr 0.49 and Pr 0.34 are not affected by this procedure.)


Procedure


1. Ensure the drive is not enabled, i.e. terminal 31 is open or Pr 6.15 is Off (0)

2. Enter 1233 (EUR 50Hz settings) or 1244 (USA 60Hz settings) in Pr xx.00.
3. Either:
• Press the red reset button
• Toggle the reset digital input
• Carry out a drive reset through serial communications by setting Pr 10.38 to 100 (ensure that Pr. xx.00 returns to 0).