viernes, 26 de abril de 2013

Tapping Machine RE24.C. Programming the driver. Steps.



Tapping Machine RE24.C. Programming the driver. Steps.

Steps for loading programs:

1.- Make sure the correct wiring of the equipment: encoder, motor and feeding.

2.- Connect the serial communications cable or converter to the computer.

3.- Download the tapping program with Winflasher and the file sequence###.bin selecting Slot 3.

4.- Download the tapping program with Winflasher and the file Ihnabilitarmotor###.bin but selecting Drive.

5.- Download the parameters program of the threading with CtSoft as the attached manual.

6.- Doing the Autotunning.

7.- Saving parameters.

jueves, 25 de abril de 2013

Tapping Machine RE24.C. Programming the driver. Deleting or Restoring Parameter Default

Tapping Machine RE24.C. Programming the driver. Deleting or Restoring Parameter Default.

Video Restoring Parameter defaults.



According to Manual Digitax ST User Guide Control Techniques:



5.6.6 Restoring parameter defaults


Restoring parameter defaults by this method saves the default values in the drive’s memory. (Pr 0.49 and Pr 0.34 are not affected by this procedure.)


Procedure


1. Ensure the drive is not enabled, i.e. terminal 31 is open or Pr 6.15 is Off (0)

2. Enter 1233 (EUR 50Hz settings) or 1244 (USA 60Hz settings) in Pr xx.00.
3. Either:
• Press the red reset button
• Toggle the reset digital input
• Carry out a drive reset through serial communications by setting Pr 10.38 to 100 (ensure that Pr. xx.00 returns to 0).

Tapping Machine RE24.C. Programming the driver. Saving parameters.

Video. Saving parameters.

According to Manual Digitax ST User Guide Control Techniques:


5.6.5 Saving parameters

When changing a parameter in Menu 0, the new value is saved when pressing the Mode button to return to parameter view mode from parameter edit mode.
If parameters have been changed in the advanced menus, then the change will not be saved automatically. A save function must be carried out.

Procedure
Enter 1000* in Pr. xx.00
Either:
• Press the red reset button
• Toggle the reset digital input
• Carry out a drive reset through serial communications by setting
Pr 10.38 to 100 (ensure that Pr. xx.00 returns to 0).

* If the drive is in the under voltage trip state or is being supplied from a low voltage DC supply, a value of 1001 must be entered into Pr xx.00 to
perform a save function.